190-P1 Pressure CFR Data Logger

CFR data logger, Model no. VAC- 190-P1
Pressure measuring range: 1 mbar to 4 bar
Accuracy: ±20 mbar
Resolution: 1mbar
Battery: 1/2 AA lithium battery
Battery life: 2500 hr
Measuring rate: 1s to 24hr

Days
Hours
Mins
Secs
1

VSKU: 1000000072

15,606.48 USD 15,606.48 USD 15606.48 USD

54,593.00 AED

    This combination does not exist.


    Add to Cart Buy Now

    Category:

  • Data Logger

  • Data logger for monitoring overpressure

    The HACCP Pressure data logger is used in monitoring and documenting overpressure in pasteurisation and sterilization operations. It can facilitate concurrent programming and readout of multiple CFR data lodge assisted by the multifunction case. Two different batteries are used for different temperature conditions. It can measure up to 60,000 values. The device is durable, robust, and reliably tight with HACCP certification.

    Applications

    1. The data logger monitors the pressure in pasteurisation and sterilization operations. 

    2. It is used in food production units.

    3. The device is in saturated pressure measuring in pasteurisation and sterilization operations for efficient monitoring of measurements.

    4. It can be utilized for parallel programming and readout for a maximum of 8 data loggers with a 190 CFR software.

    5. The device can be used in the freeze-drying operation.

    Features

    1. The data logger has an absolute pressure accuracy ranging from 1 mbar to 4 bars range.

    2. The device is durable and robust.

    3. It is reliably tight, even after changing the battery.

    4. It facilitates concurrent programming and readout of multiple CFR data lodge assisted by the multifunction case.

    5. The battery can be changed quickly saving time and increasing efficiency.

    6. The device is HACCP certified.

    7. It can measure pressure precisely.

    8. It has a memory storage capacity of 60,000 measured readings.

    9. The device is small and slim.

    10. The device has a diameter of 20 mm.

    11. A high-temperature resistant polyether ether ketone (PEEK) coating is applied to the battery housing.

    12. The device has a flexible height.

    13.  The HACCP data logger can vary in size with respect to two types of battery.

    14. The small battery makes the logger's size very compact.

    15. The larger battery is suitable at low temperatures measurements.

    16. The data logger is totally tight even after changing the batteries.

    17. The multifunction case can is utilized for concurrent parallel programming and readout of up to 8 data loggers.

    18. The 190 CFR software programs and simultaneously reads out the data logger.

    19. The 190 CFR software analyzes the measured data on the PC.

    20. It provides help at critical points during inputs through warning indications.

    21. The software with the guided measurement and documentation operation generates the output file in one click.

    22. The measuring equipment and battery are kept in two separate housings.

    23. The device is 21 CFR Part 11-compliant.

    Specifications

    1. The measuring range of absolute pressure is from 1 mbar to 4 bar.

    2. The absolute pressure accuracy is ±20 bar.

    3. The absolute pressure resolution is 1mbar.

    4. It has a dimension of 22 x 83 (ø x height).

    5. The device operates at a temperature varying from 0 to 140 °C.

    6. The storage temperature varies from -20 to +50 °C.

    7. It is provided with  1/2 AA lithium battery.

    8. The Battery can serve for 2,500 operating hours (measuring cycle 10 sec at +121 °C).

    9. It has a storage capacity of  60,000 measuring values.

    10. The instrument has class IP68 protection.

    11. The measuring rate varies from 1s to 24hr.

    12. The housing material of the device is Stainless steel and PEEK plastic.

    13. The device has a single channel.

    14. It has a CE certification.

    15. The small battery has an operational temperature range of -20 to +140 °C

    16. The large battery has an operational temperature of  -50 to +140 °C.

    17. 190 CFR software is used for generating output.

    18. The device is 21 CFR Part 11-compliant.

    We supply these 190-P1 CFR data logger for monitoring overpressure and in the pharmaceutical industry in the USA, UK, Germany, France, Netherlands, Spain, Switzerland, Sweden, and other European countries. Also, we supply these 190-P1 CFR data logger for monitoring overpressure and in the pharmaceutical industry in the Middle East and other Asian countries including India, Pakistan, Afghanistan, Bangladesh, Singapore, etc.

    Our African offices supply these  190-P1 CFR data logger for monitoring overpressure and in the pharmaceutical industry in all African countries covering South Africa, Kenya, Nigeria, Tanzania, Rwanda, Djibouti, Morocco, Ghana, Ethiopia, Uganda, Morocco, Tunisia, Cameroon, Mauritius, Gabon, Seychelles, etc.

    Our Middle East offices supply these 190-P1 CFR data logger for monitoring overpressure and in pharmaceutical in the United Arab Emirates, Kingdom of Saudi Arabia, Qatar, Oman, Kuwait, Egypt, Lebanon, Bahrain, Libya, Iraq, Erbil, Jordan, etc.

    This is a preview of the recently viewed products by the user.
    Once the user has seen at least one product this snippet will be visible.

    Recently viewed Products

    To install this Web App in your iPhone/iPad press and then Add to Home Screen.